BitFury commits to liquid cooling It's the largest data center deployment yet using 3M Novec cooling fluid.When Bitcoin miner and infrastructure provider BitFury Group acquired liquid cooling provider Allied Control it was clear that BitFury was serious about investing in data center technology.Though half of its existing data centers were up and running in Iceland, where free air cooling is a matter of course, expansion plans in other parts of the world, combined with the huge power requirements for the ASIC-based mining systems, made liquid cooling a leading candidate for its next generation data centers.As we speculated in coverage of the announcement of its next set of data centers in Georgia, BitFury has acknowledged that its new facility will make use of Allied Control's two-phase immersion cooling (2PIC) While other immersion cooling providers, such a Green Revolution Cooling, use basic mineral oil as he immersion media, the 2PIC system from Allied Control makes use of 3M Novec Engineered Fluid, a custom designed immersion coolant with a low boiling point optimized for 2PIC style immersion cooling.In this environment, the low boiling point of the fluid means it rapidly turns to vapor, carrying the heat of the submerged components with it to the water-cooled condenser coil, which then uses gravity to drop the fluid back into the immersion tank.
This method requires no pumps to circulate the fluid, adding to the efficiency of the cooling solution.The design goal for the start-up of the 40 MW BitFury data center in Georgia is specifying 250 KW per rack, with the potential to draw even more power as BitFuy continues to develop higher performance ASIC designs for bitcoin mining.This is more than 10 times the power per rack supported in most high-end data centers and makes the additional cost of the immersion cooling technology and specialized cooling fluids much more practical.× Please review our terms of service to complete your newsletter subscription I agree to the Terms of Use, Privacy Policy and Video Services Policy.I understand I will receive a complimentary subscription to TechRepublic's News and Special Offers newsletter, and the Daily Digest newsletter (you can opt out at any time).ACCEPT & CLOSE You have been successfully signed up.To sign up for more newsletters or to manage your account, visit the Newsletter Subscription Center.
PIC's Oil Cooled Data Center Austin, TX (PRWEB) April 19, 2017 Green Revolution Cooling (GRC), a leader in immersion cooling, today announced key performance and reliability results from its installation at Port d’Informació Científica (PIC) in Barcelona, Spain.The ultra-efficient cluster installed in October 2015 has since been used to process dozens of Petabytes of data from CERN's Large Hadron Collider, and leading-edge astrophysics projects.“The GRC system has beaten all expectations in terms of performance and reliability,” said Vanessa Acin Portella, IT Team Leader at PIC.“We’ve had zero server or cooling failures in the 18 months that the system has been running.” GRC’s oil immersion cooling system, as the name suggests, immerses servers in an oil bath.The mineral oil based coolant called ElectroSafe, is an electrical insulator with 1,200x the heat capacity of air, making it ideal for cooling IT equipment.There are several advantages of using immersion cooling over traditional air cooling, this technique eliminates the need for any type of air conditioning or specialized facility design for data centers.
This reduces the upfront cost of building a data center facility, while reducing energy use by up to 50%.Apart from the cost savings, the system also helps improve server reliability by protecting them from hot spots, dust, moisture, oxygen, and vibrations.bitcoin wieviel euroAnother key feature of the PIC facility is that it has zero water consumption.purchase litecoin onlineData center water utilization has been a growing concern lately.bitcoin speculation redditTraditional air cooled data centers consume large amounts of water to support chillers and air conditioning systems.litecoin price poundsGRC’s immersion cooling technology, on the other hand, can eliminate water consumption by using dry coolers instead of evaporative cooling towers in most climates.ceo bitcoin exchange found dead
“Water is the next frontier for data center efficiency and sustainability,” said Christiaan Best, Founder and CTO of GRC.“Delivering waterless cooling around the year, is just another way we’re helping environmentally conscious customers [like PIC] achieve their data center and sustainability goals,” he added.ethereum cold storage“The [GRC] system’s ability to support close to 50kW of IT load per rack, without any air conditioning, refrigerant, or water use is what made it attractive to us,” added Vanessa.“We had limited space, power, and cooling.GRC’s technology made it possible to add capacity in a storage area, while reducing power requirements by 30%.” Given the superior reliability and performance of the GRC system, PIC plans to explore the use of custom whitebox hardware to further exploit the cost savings offered by the GRC System.About PIC Created in 2003, PIC is a joint undertaking of the Spanish and Catalan governments through CIEMAT and IFAE.
PIC has been designated by the Spanish government as its LHC Tier-1 centre, and it is the main (Tier-0) data centre for the MAGIC telescope and the PAU dark energy survey.PIC is also a Scientific Data Center for the EUCLID satellite of the European Space Agency and is ramping up its support for the next-generation Cherenkov Telescope Array (CTA).PIC maintains a transversal innovation activity with many significant results over the years, related to software, hardware, monitoring and energy efficiency.Visit http://www.pic.es for more information.About GRC Green Revolution Cooling is a pioneer and leader in the liquid immersion cooling market for data centers.GRC’s CarnotJet System, a rack-based immersion cooling system for servers, uses a mineral oil based dielectric coolant that eliminates the need for chillers, air conditioners, and air handlers.Thereby, helping cut data center construction costs by up to 60%, while reducing data center cooling energy by up to 95%.GRC’s solutions have helped some of the largest cloud, HPC, and telecom organizations build extremely efficient, cost effective, and resilient data centers across the globe.